返回 产品详情
美国NDT James C-CL-3000 Chlorimeter混凝土氯离子含量测定仪
来自倍加孚(厦门)科技有限公司
¥面议元/
发布时间  2024-03-27 关注次数  331
倍加孚(厦门)科技有限公司
家家通 6年
图文介绍 产品参数 供应商信息

美国NDT James C-CL-3000 Chlorimeter混凝土氯离子含量测定仪

美国NDT James  C-CL-3000 Chlorimeter混凝土氯离子含量测定仪


The Chlorimeter Chloride Test System

A field kit for the determination of chloride ion content in concrete, fresh cement, masonry, most other construction materials, and water.

Applications

Service life prediction

Corrosion analysis

Features & Benefits

Fast - Results within minutes at the site.

Economical - Low cost per sample compared to laboratory testing.

Accurate - Results are comparable to laboratory testing.

Covers wide range from 0.002% to 2% chloride by weight

Internal Memory to store readings for later upload to a PC  via USB.

Digital display for direct reading of percentage of chloride by weight.

Conbs to AASHTO-T- 260.

Menu in English and Spanish.

The Chlorimeter produces results on-site, within minutes that are accurate and comparable to expensive laboratory tests. It measures the electrochemical reb of a weighted sample placed in an extrb liquid. It automatically shows a temperature compensated reading of percent of chlorides on its digital display. A wide range - from 0.002 to 2% chloride by weight - is covered.

Technical

The determination of the chloride ion concentration in concrete is essential in assessing the need for maintenance on, for example, bridge decks and parking structures. The test can also be used to ensure that materials used in new construction are free from potentially harmful chloride ion levels.

With this b, the concentration of acid soluble chlorides is measured. In most cases, this is equivalent to total chloride concentration.

A sample of powder is obtained by drilling and careful quartering. Then an accurately weighed 3 gr. (0.1 oz) sample is dissolved in 20 ml (0.67 fl. oz.) of extrb liquid which consists of a precise, measured concentration of acid. For sampling wet concrete a 3 gr. (0.1 oz.) sample of mortar (i.e. without coarse aggregate) is used.  Typically for concrete, samples that are to be analyzed for chloride are obtained at various depths, thereby supplying the engineer with a chloride ion profile.


The chloride ions react with the acid of the extrb liquid in an electrochemical reb. An electrode, with integral temperature sensor, is inserted into the liquid and the electrochemical reb measured.

A uniquely designed instrument converts the voltage generated by the chloride concentration and sensor into a reading for the user. The instrument automatically applies the temperature correction and it shows the chloride concentration on a LCD display percentage by weight.  The unit uses 4 'AA' batteries for power.  The Chlorimeter can also store test results and upload them to PC via USB.


Once the sample is obtained, test results can be determined and read in less than five minutes.  These initial values give a valuable indicator of the current chloride concentration values.  Accurate results are typically obtained after the sample has been in the extrb liquid for 24 hours.


To avoid contamination, the electrode should be thoroughly washed with de-ionized water after each test.

Replacement packs, containing twelve bottles of extrb liquid, each for one time use, are available. Five calibration liquids each with known concentrations are supplied with each pack.  Bulk packs of one hundred extrb liquids are also available for larger testing jobs.


Thecalibration liquids are used to establish the calibration curve, and to check that the system is functioning correctly. Calibration is not required for each use. The calibration liquids are colored to avoid confusion between them and with the extrb liquid.


All equipment necessary to complete the chloride test is supplied in a standard size carrying case.


Components


C-CL 3700 Chloride combination electrode with externally mounted temperature sensor, cable, and connectors.
C-CL 3020 Battery powered, high impedance, electronic meter, with temperature compensation circuits and microprocessor for direct conversion to percentage of chloride.  Uses four 'AA" size batteries.
C-CL 2012 Optional pack of 12 jars each with 20 ml (0.67 fl. oz.) of extrb liquid and 5 jars of colored calibration liquid.
C-CL 1030 Bottle of electrode wetting agent.
C-CL 2096 Optional bulk pack of 100 jars extrb liquid and 20 jars of colored calibration liquid.


美国NDT James  C-CL-2000 Chlorimeter混凝土氯离子含量测定仪 这是一个能装在手提箱内的测量混凝土内含氯量的试验室。   特 性 : 『 在工地现场,能在几分钟内快速测得混凝土的含氯量。 『 与试验室分析相比,费用低廉。 『 与试验室试验相比,结果准确。 『 环境温度变化时,仪器具有自动补偿功能。 『 含氯量以百分比和 ppm 表示,可直接读数。   工作原理 : 『 混凝土内含氯量十分重要,桥面及停车场等混凝土内的含氯量的评估尤为关键,因为这直接关系到确定该构筑物是否需要维护及确定其维护范围的大小。混凝土内增添新材料时也能对其含氯量进行分析,从而避免混凝土结构受到过高含氯量的损害。 用这种方法可以测出混凝土内酸溶性氯化物的含量,其单位为重量百分比和 ppm 浓度。在大多数情况下,上述数值与总含氯量是相当的。『 在混凝土构筑物上,用钻孔法取样,将钻出的 3 克混凝土粉溶入 20 毫升的酸性萃取液内,萃取液的浓度是经过精确标定的。混凝土中的氯离子与萃取液中的酸发生电化学反应。 『 将一个带温度传感器的电极,插入上述萃取液中,对电化学反应进行测量,经特殊设计的仪器能把氯化物反应所产生的电压经温度修正后转换为含氯量的浓度,直接在液晶显示器上显示。 『 一旦获取混凝土粉样品,用该仪器在几分钟之内即可得到准确结果。 『 为避免污物影响测量精度,每次测试前应用蒸馏水对电极加以彻底清洗。 『 仪器带有一盒萃取液,内装 12 瓶,每次测试用一瓶。盒内还有两瓶校准液,每瓶校准液的浓度已预先标定,其用途是使操作者能校准仪器的精度。为避免在使用中发生混淆,校准液有两种颜色,一瓶是红色的,一瓶是蓝色的。 『 所有与含氯量有关的东西都装在一个手提箱内,携带十分方便。   C-CL-2000 混凝土含氯量测定仪由下述部分组成: C-CL-3700 带有温度补偿传感器的氯化物测量电极 C-CL-2020 由电池供电用来直接显示氯的百分含量的带有温度补偿电路和微处理器的高阻抗读数器 C-CL-2012 备件盒。内有塑料瓶装萃取液 12 瓶,每瓶 20ml ,盒内还有 5 瓶有颜色的校准液 C-CL-1030 电极浸润剂瓶    以上是美国NDT James  C-CL-3000 Chlorimeter混凝土氯离子含量测定仪   美国NDT James相关产品介绍: 美国NDT James T-HT-1000 Humiditest混凝土钻孔湿度测试仪 美国NDT James T-C-10 T-C-20 Cementometer微波水泥含水率测试仪 美国NDT James T-S-30 Aquaprobe微波土壤含水率测试仪 美国NDT James T-M-170 Aquameter混凝土含水率测试仪 美国NDT James T-T-90 Trident插针式微波骨料含水率测试仪 美国NDT James I-CB-6000 Carbo Detect混凝土碳化深度酸碱指示剂 美国NDT James I-AS-3000 ASR-Detect混凝土碱骨料反应测试仪 美国NDT James A-AB-1200 A-AV-1300 A-AA-1100 Air Meters混凝土含气量测试仪 美国NDT JAMES Z-WP-1000 Windsor Probe混凝土强度枪击检测仪 美国NDT JAMES W-P-2000 Windsor Pin混凝土强度检测仪 美国NDT JAMES R-HR-8000 Mini R-Meter钢筋定位仪 美国NDT JAMES P-C-7300 Bond Test MK III粘结强度测试仪 美国NDT JAMES P-C-728 P-C-729 Anchor锚栓测试仪 美国NDT JAMES M-M-3056 Maturity Meter混凝土成熟度测试仪 美国NDT JAMES Datascan MK II钢筋混凝土钢筋扫描仪 美国NDT James C-P-6000 C-P-6050 Porosiscope混凝土渗气渗水性测试仪 美国NDT James C-CM-4000 Cor-Map钢筋锈蚀检测仪 美国NDT James C-CL-3000 Chlorimeter混凝土氯离子含量测定仪 美国NDT James W-M-350 W-M-250 Rebound Hamme机械回弹仪 美国NDT James W-D-2000 Rebound Hamme数字回弹仪 美国NDT James V-E-1000 E-Meter MK II动态弹性模量测试仪 美国NDT James V-V-100 Vu-Con冲击回波测试仪 美国NDT JAMES V-C-400 V-Meter MK IV混凝土超声波测试仪 美国NDT James C-CS-8000 C-CS-8300 Gecor 8钢筋锈蚀程度测定仪 美国NDT James C-RM-8000 Ohmcorr混凝土电阻率测定仪 美国NDT James C-CM-5000 Cor-Map II大屏幕半电池电压钢筋锈蚀检测仪 美国NDT JAMES R-C-400/450/475/410 Rebarscope钢筋扫描仪
倍加孚(厦门)科技有限公司
  • 公司类型私营有限责任公司
  • 经营模式生产加工-私营有限责任公司
  • 联系人林经理
  • 联系手机18059876689
  • 联系固话0592-6054838
  • 公司地址厦门市湖里区永嘉新工业区后埔东里18-114号
主营业务
红外测温仪 辐射测温仪 双色高温计 热风炉红外测温仪
倍加孚(厦门)科技有限公司致力于高精度红外线测温仪、光纤温度传感器、红外温度传感器、高温比色测温仪等研发生产和系统应用。   研发产品:工业红外线测温仪、红外测温仪、红外光学高温计、窑炉测温装置、焚烧炉测温装置、光纤温度传感器、光纤红外测温仪、DCTQ 铸造用连续测温仪、铝专用测温仪、锻造热处理温度传感器、锻造测温仪、非接触红外热电偶、火焰监测器、点式光纤温度传感器等,为工业用户提供一站式测温解决方案。   产品已广泛应用于石油、化工、冶金、陶瓷、电力、高校、科研院所等多个领域。公司自成立以来一直秉承“诚实守信,精益求精”的理念,全心全意为您服务,为工业用户提供测温解决方案。   “圣加弗PLUSFO”、安全的温度传感器生产商,“圣加弗”愿作您永远的朋友,与您携手合作双赢。
林经理 电话咨询 立即询价